Overview
Capacity
42,000 BTU/h (3.5 ton)
Voltage
230V
Type
Outdoor Condenser
Performance (AHRI certified)
Rated system
AHRI 215387266 (ductless indoor units)
Cooling capacity (95°F)
42,000 BTU/h
Heating capacity (47°F)
42,000 BTU/h
Heating capacity (17°F)
31,000 BTU/h
Heating capacity (5°F)
30,000 BTU/h
SEER2
22.0
EER2
11.2
HSPF2
10.0
COP at 5°F
2.0
Capacity
Number of zones
2 - 5
Cooling capacity 95°F, non-ducted (min - max)
42,000 (8,700 - 47,000) BTU/h
Heating capacity 47°F, non-ducted (min - max)
42,000 (8,700 - 47,000) BTU/h
Electrical
Power supply
208-230V / 1Ph / 60Hz
MCA
28 A
MOCP (max breaker)
45 A
Dimensions & weight
Dimensions (W×H×D)
1074 x 853 x 468 mm
Net / gross weight
174.2 / 198.4 lbs (79 / 90 kg)
Refrigerant & piping
Refrigerant / factory charge
R454b / 120.02 oz
Pre-charged length (total)
123 ft (37.5 m)
Ports (liquid - gas)
5 x 1/4 - 3/8 in
Max line length (each / total)
98 ft (30 m) / 295 ft (90 m)
Max height difference
49 ft (15 m) ODU to furthest IDU; 33 ft (10 m) between IDUs
Operating range
Cooling operating range (outdoor)
5 ~ 133°F (-15 ~ 55°C)
Heating operating range (outdoor)
-13 ~ 86°F (-25 ~ 30°C)
Sound & airflow
Airflow (outdoor)
2,000 CFM
Sound pressure (outdoor)
65 dB(A)
AHRI certified ratings
AHRI 215387270Ducted41,000 BTU/h · SEER2 19.5 · HSPF2 9.0📄 Download certificate
AHRI 217598666Mixed41,500 BTU/h · SEER2 21.0 · HSPF2 9.0📄 Download certificate
AHRI 215387266Ductless42,000 BTU/h · SEER2 22.0 · HSPF2 10.0📄 Download certificate